PLC, HMI, SCADA, INVERTERS, GSD PROFIBUS,
GSDML PROFINET, EDS CanOpen, INDUSTRIAL AUTOMATION

23:48
Demag Cranes Dedrive Compact STO ANYBUS-IC Profibus DP slave VEC_0696.GSD

HMS Industrial Networks AB, Demag Cranes & Components GmbH

VEC_0696.zip - VEC_0696.GSD 

21477044_070307.pdf - Operation instructions Communication module CM-PDP-24 (Profibus-DP) Supplement of the operation instructions Frequency Inverter (0,75 up to 55 kW) / Valid from the frequency software version 4.2.4/050-6

=============================================================
Profibus Device Database of :
HMS Industrial Networks AB DP slave
Model : ANYBUS-IC PDP 
Description : ANYBUS-IC Profibus DP slave
Language : English
Date : 12 September 2001
Author : HMS Industrial Networks AB, Demag Cranes & Components GmbH
Modification 02.10.03: Model_Name 
============================================================= 
#Profibus_DP

GSD_Revision        = 2

; Device identification
Vendor_Name         = "HMS Industrial Networks AB"
Model_Name          = "Dedrive Compact"
Revision            = "Version 1.00"
Ident_Number        = 0x0696
Protocol_Ident      = 0              ; DP protocol
Station_Type        = 0              ; Slave device
FMS_supp            = 0              ; FMS not supported
Hardware_Release    = "Version 1.02"
Software_Release    = "Version 1.00"

; Supported baudrates
9.6_supp            = 1
19.2_supp           = 1
45.45_supp          = 1
93.75_supp          = 1
187.5_supp          = 1
500_supp            = 1
1.5M_supp           = 1
3M_supp             = 1
6M_supp             = 1
12M_supp            = 1

; Maximum responder time for supported baudrates 
MaxTsdr_9.6         = 60
MaxTsdr_19.2        = 60
MaxTsdr_45.45       = 250
MaxTsdr_93.75       = 60
MaxTsdr_187.5       = 60
MaxTsdr_500         = 100
MaxTsdr_1.5M        = 150
MaxTsdr_3M          = 250
MaxTsdr_6M          = 450
MaxTsdr_12M         = 800

; Supported hardware features
Redundancy          = 0       ; not supported
Repeater_Ctrl_Sig   = 2       ; TTL
24V_Pins            = 0       ; not connected
Implementation_Type = "SPC3"

; Supported DP features
Freeze_Mode_supp    = 1       ; supported
Sync_Mode_supp      = 1       ; supported
Auto_Baud_supp      = 1       ; supported
Set_Slave_Add_supp  = 1       ; supported

; Maximum polling frequency
Min_Slave_Intervall = 1       ; 100 us

; Maximum supported sizes
Modular_Station     = 1       ; modular
Max_Module          = 24
Max_Input_Len       = 48
Max_Output_Len      = 48
Max_Data_Len        = 96
Modul_Offset        = 1

Fail_Safe           = 1       ; state CLEAR accepted

Slave_Family        = 1       ; Drives
Max_Diag_Data_Len   = 6


; UserPrmData: Length and Preset
Max_User_Prm_Data_len = 16
Ext_User_Prm_Data_Const(0)  = 0x00
Ext_User_Prm_Data_Const(1)  = 0x00
Ext_User_Prm_Data_Const(2)  = 0x00
Ext_User_Prm_Data_Const(3)  = 0x00
Ext_User_Prm_Data_Const(4)  = 0x00
Ext_User_Prm_Data_Const(5)  = 0x00
Ext_User_Prm_Data_Const(6)  = 0x00
Ext_User_Prm_Data_Const(7)  = 0x00
Ext_User_Prm_Data_Const(8)  = 0x00
Ext_User_Prm_Data_Const(9)  = 0x00
Ext_User_Prm_Data_Const(10) = 0x00
Ext_User_Prm_Data_Const(11) = 0x00
Ext_User_Prm_Data_Const(12) = 0x00
Ext_User_Prm_Data_Const(13) = 0x00
Ext_User_Prm_Data_Const(14) = 0x00
Ext_User_Prm_Data_Const(15) = 0x00


; Definition of modules
Module = "PPO1: 4 Words PKW, 2 Words PZD" 0xF3 , 0x71
EndModule
;
Module = "PPO2: 4 Words PKW, 6 Words PZD" 0xF3 , 0x75
EndModule
;
Module = "PPO3: 2 Words PZD" 0x71
EndModule
;
Module = "PPO4: 6 Words PZD" 0x75
EndModule

Категория: Demag Cranes & Components GmbH | Просмотров: 37 | Добавил: gt7600 | Рейтинг: 5.0/1