08:46 SIEMENS 46817803 Sending Emails to SMTP Servers with an S7 CPU S7-1500 and S7-1200 PLCs | |
46817803_Archiv_en.zip - In the archive, you will find the documentation and sample projects for sending unsecure emails with the FB "PN_Mail". 46817803_Email_with_SimaticS7.zip - Sample project for TIA Portal V17 (835,8 KB) 46817803_EMail_with_SimaticS7_V3_2_en.pdf - APPLICATION EXAMPLE Sending of emails over secure connections with S7-1500 and S7-1200 PLCs / Entry-ID: 46817803 V3.2 04/2026 Тип сообщения: Пример использования ID сообщения: 46817803, Дата сообщения: 15.04.2026Sending Emails to SMTP Servers with an S7 CPU IMATIC S7 stations also allow the use of email as the default mechanism for transmitting error conditions or warnings from industrial plants to a control center or operating staff. Nowadays, for security reasons, most email service providers only support an encrypted connection to their SMTP servers. The following Ethernet ports can be used to set up a secure connection (SMTP over TLS) to an email server and send an email from the user program using the "TMAIL_C" instruction.
Setting up a secure email connection requires the following steps that are described in the application example:
Download Note
Archive
In the archive, you will find the documentation and sample projects for sending unsecure emails with the FB "PN_Mail". | |
|
| |
| Всего комментариев: 0 | |