siemense_cnc_44sp1.pdf
MLFB
6FC5851-1XG40-1YA0
SINUMERIK 840D SL
CNC SOFTWARE 31-3
WITH SINUMERIK Operate, 6 LANGUAGES
EN,DE,FR,IT,SP,V-CH
SOFTWARE 4.4 SP1
ON CF-CARD WITH LICENSE
6FC5851-1YG40-1YA0
SINUMERIK 840DE SL
CNC SOFTWARE 31-3 Export
WITH SINUMERIK Operate, 6 LANGUAGES
EN,DE,FR,IT,SP,V-CH
SOFTWARE 4.4 SP1
ON CF-CARD WITH LICENSE
The CNC Software 4. SP1 (internal version 04.04.01.00.012) comprises the following components:
Component Version
NCK V83.03.05
SNCK V02.06.00.00.001
SINAMICS V04.40.23.17
PLC Op. Sys. V32.70.20
FB15(sl) V04.04.11
CP V02.05.01
MCP CLIENT V01.04.36
SINUMERIK Operate V04.04.01.00.009
Linux basic system V04.40.35.00
NCK file system driver V04.04.00.00.003
Profinet FW 04.01.33.50
Cycles V04.04.20.00
SNC V01.04.00.00.005
Requirements:
- The CNC SW 4.4 SP1 can only be operated on SINUMERIK NCUs 7x0.3 PN.
- CF Card Smart Modular Xceed 8GB. A specific CF card is required for the CNC software:
- - For the export version 6FC5851-1YG40-0YA8 or 6FC5313-6AG00-0AA0
- - For the standard version 6FC5851-1XG40-0YA8.
- No standard versions may be operated on CF cards which are licensed for the export version because,
- in this case, NC-Start is disabled.
- Step 7 Version 5.5 HF4 (or later)
- Toolbox 4.4.8
- NCU Service System V04.40.35 (or later)
- NCU 730.3 PN with BIOS Version V16.0.0.0 (with PLC Bootloader V2.0)
- If required, startup tool resp. HMI-Advanced V7.6 SP2 HF2 (or later) for drive commissioning
- If required, SINUMERIK Operate V2.7 SP1 for PCU 50 resp. PC / PG
Installing the CNC software:
The NCU service system V04.40.35 (or later) is required on USB stick to install the CNC software.
New installations can be performed via the NCU service system and TCU or with WinSCP / RCS Commander.
The software may only be installed on a Smart Modular XceedCF 8GB card – see prerequisites.
Installing the NCU service system on USB stick:
The NCU service system is stored as USB stick image in the directory emergency_bootsys_ncu of the DVD delivered. The copy program installdisk.exe is also included. Connect a USB stick >= 2 GB to your PG resp. PC (with Windows XP) and determine the relevant drive letter. Call up installdisk to copy the NCU service system onto the USB stick:
installdisk --verbose --blocksize 1m <image file> <drive letter:>
We recommend that you execute this command in a DOS shell.
For this, you require administrator rights on your PG/PC.
Upon completion of installdisk, remove the USB stick from the PG / PC, boot once an NCU 7x0 from this stick (this boot process takes a little bit longer; a "P" in the 7-segment display of the NCU indicates that the FAT partition of the USB stick is partitioned) and reinsert the stick in the PG / PC. Windows now displays an empty USB stick. Copy the requested CNC software (file with the extension .tgz) from the DVD delivered, the directory ncu_sw.
The USB stick can be inserted in one of the two USB plugs of the NCU 7x0.3. After being switched on, the NCU is booted from this USB stick. The system is operated either via a TCU which is connected to the NCU or via PG / PC using WinSCP under "Open Terminal".
The use of the NCU service system is described in the documentation /IM7/ on the DVD delivered.
We recommend that you use the USB stick "SIMATIC IPC USB Flashdrive, 6ES7648-0DC50-0AA0".
Alternatively, the image can be installed with the RCS Commander (6FC5860-7YC10-1YA0) via the menu item "Write file system image". |