DELA08DB.GSD
;==========================================================
; GSD-File for Delta CMC-PD01
;
; Auto_Baud_supp, 12MBaud
;
; Stand :
; File : deltpd01.GSD
;===========================================================
#Profibus_DP
; Unit-Definition-List:
GSD_Revision = 1
Vendor_Name = "Delta Electronics"
Model_Name = "C2000 DRIVES"
Revision = "Rev. 1"
Ident_Number = 0x08DB
Protocol_Ident = 0 ; PROFIBUS DP
Station_Type = 0 ; DP-slave
FMS_supp = 0
Hardware_Release = "V1.0"
Software_Release = "V1.0"
Redundancy = 0
Repeater_Ctrl_Sig = 2 ; TTL
24V_Pins = 0
Implementation_Type = "SPC3"
Bitmap_Device = "VFDDRV"
Bitmap_Diag = "VFDDRV"
Bitmap_SF = "VFDDRV"
Slave_Family = 1@TdF@Delta VFD Drives ; Drives family
; Supported Communication Speeds:
Auto_Baud_supp = 1
9.6_supp = 1
19.2_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
; DP_Slave Information:
Freeze_Mode_supp = 1
Sync_Mode_supp = 1
Set_Slave_Add_supp = 0
Min_Slave_Intervall = 1 ; 100 micro-second
; Module-Definitions:
Modular_Station = 1 ; 0-compact; 1-modular
Max_Module = 1
Max_Input_Len = 60
Max_Output_Len = 60
Max_Data_Len = 120
Modul_Offset = 0
Fail_Safe = 0
Max_Diag_Data_Len = 16
ORDERNUMBER="PD-01"
;zr modify ok
;specify the user parameters:
Max_User_Prm_Data_Len = 51
User_Prm_Data_Len = 51
User_Prm_Data = 0x00,0x00,0x00,\
0x20,0x00,\
0x20,0x01,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x21,0x01,\
0x21,0x02,\
0x21,0x03,\
0x21,0x04,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x00,\
0x00,0x02,\
0x00,0x02,\
0x00,0x01,\
0x00,0x00
;type modify ok zr
Module = "4 PKW, 2 PZD (PPO 1) " 0xF3, 0xF1
EndModule
Module = "4 PKW, 6 PZD (PPO 2) " 0xF3, 0xF5
EndModule
Module = "0 PKW, 2 PZD (PPO 3) " 0x00, 0xF1
EndModule
Module = "0 PKW, 6 PZD (PPO 4) " 0x00, 0xF5
EndModule
Module = "4 PKW, 10 PZD (PPO 5) " 0xF3, 0xF9
EndModule
Module = "4 PKW, 4 PZD " 0xF3, 0xF3
EndModule
Module = "0 PKW, 4 PZD " 0x00, 0xF3
EndModule
; Extended Description of User-Parameters
PrmText = 1
Text(0) = "Ignore and Continue"
Text(1) = "Stop accord to Pr.STOP METHOD"
EndPrmText
PrmText = 2
Text(0) = "Stop DataExchange & Report Fault"
Text(1) = "Continue & Report Alarm"
Text(2) = "Ignore & Continue DataExchange"
EndPrmText
ExtUserPrmData = 1 "Data Output 1(CMC-PD01 -> VFD)"
Unsigned16 0x2000 0-65535
EndExtUserPrmData
ExtUserPrmData = 2 "Data Output 2"
Unsigned16 0x2001 0-65535
EndExtUserPrmData
ExtUserPrmData = 3 "Data Output 3"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 4 "Data Output 4"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 5 "Data Output 5"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 6 "Data Output 6"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 7 "Data Output 7"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 8 "Data Output 8"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 9 "Data Output 9"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 10 "Data Output 10"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 11 "Data Input 1(VFD -> CMC-PD01)"
Unsigned16 0x2101 0-65535
EndExtUserPrmData
ExtUserPrmData = 12 "Data Input 2"
Unsigned16 0x2102 0-65535
EndExtUserPrmData
ExtUserPrmData = 13 "Data Input 3"
Unsigned16 0x2103 0-65535
EndExtUserPrmData
ExtUserPrmData = 14 "Data Input 4"
Unsigned16 0x2104 0-65535
EndExtUserPrmData
ExtUserPrmData = 15 "Data Input 5"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 16 "Data Input 6"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 17 "Data Input 7"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 18 "Data Input 8"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 19 "Data Input 9"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 20 "Data Input 10"
Unsigned16 0x0000 0-65535
EndExtUserPrmData
ExtUserPrmData = 21 "dout_len"
Unsigned16 2 0-10
EndExtUserPrmData
ExtUserPrmData = 22 "din_len"
Unsigned16 2 0-10
EndExtUserPrmData
ExtUserPrmData = 23 "LossDPComTreat"
Unsigned16 1 0-1
Prm_Text_Ref = 1
EndExtUserPrmData
ExtUserPrmData = 24 "LossSPComTreat"
Unsigned16 0 0-2
Prm_Text_Ref = 2
EndExtUserPrmData
Ext_User_Prm_Data_Ref(3) = 1
Ext_User_Prm_Data_Ref(5) = 2
Ext_User_Prm_Data_Ref(7) = 3
Ext_User_Prm_Data_Ref(9) = 4
Ext_User_Prm_Data_Ref(11) = 5
Ext_User_Prm_Data_Ref(13) = 6
Ext_User_Prm_Data_Ref(15) = 7
Ext_User_Prm_Data_Ref(17) = 8
Ext_User_Prm_Data_Ref(19) = 9
Ext_User_Prm_Data_Ref(21) = 10
Ext_User_Prm_Data_Ref(23) = 11
Ext_User_Prm_Data_Ref(25) = 12
Ext_User_Prm_Data_Ref(27) = 13
Ext_User_Prm_Data_Ref(29) = 14
Ext_User_Prm_Data_Ref(31) = 15
Ext_User_Prm_Data_Ref(33) = 16
Ext_User_Prm_Data_Ref(35) = 17
Ext_User_Prm_Data_Ref(37) = 18
Ext_User_Prm_Data_Ref(39) = 19
Ext_User_Prm_Data_Ref(41) = 20
Ext_User_Prm_Data_Ref(43) = 21
Ext_User_Prm_Data_Ref(45) = 22
Ext_User_Prm_Data_Ref(47) = 23
Ext_User_Prm_Data_Ref(49) = 24
;============ END of GSD file for VFD Drives ===================== |