PLC, HMI, SCADA, INVERTERS, TUTORIALS, INDUSTRIAL AUTOMATION

00:50
SICK GSDML-V2.3-SICK-RFH6xx-20131010.xml

GSD_file_PROFINET_for_RFH6xx_DC0004663.ZIP 

GSDML-V2.3-SICK-RFH6xx-20131010.xml 

Company    : SICK AG 
Product : RFH6xx 
===================================================================================
RFH6xx                           - Sensor -
===================================================================================
RFH6xx V3.00 (or higher):
- Profinet IO on board is supported 
- GSD-Parameterization is supported

Note:
- In the HW-Config four modules are required:
  Ctrl-Bits In
  Ctrl-Bits Out
  xx Byte Input  (HS or NH)
  xx Byte Output (HS or NH)

Functions ==================================================================================
- 1 port Profinet device
- SICK proxy (parameterization via Sopas-ET)
- Ctrl-Bits               (compatible to CDF600-2 Profinet/Profibus)
- Input/output data bytes (compatible to CDF600-2 Profinet/Profibus)

- SICK functionblock for Siemens S7 can be used:
  http://www.sick.com/software  
  select category: 'Function block'
===================================================================================

Категория: SICK | Просмотров: 105 | Добавил: Admin | Теги: Sick, RFH | Рейтинг: 0.0/0