PLC, HMI, SCADA, INVERTERS, GSD PROFIBUS,
GSDML PROFINET, EDS CanOpen, INDUSTRIAL AUTOMATION

22:05
SIEMENS SIMATIC S7-200 SMART, PROFIBUS DP Slave module siem81C7.gsd

SIEMENS SIMATIC S7-200 SMART, PROFIBUS DP Slave module siem81C7.gsd

SIMATIC S7-200 SMART, PROFIBUS DP Slave module, 9.6 KB to 12 MB, 1 interface PROFIBUS-DP/MP

6ES7 288-7DP01-0AA0 - siem81C7.gsd 

;======================================================
; GSD File for the EM DP01 PROFIBUS-DP with a DPC31
;
; MLFB  : 6ES7 288-7DP01-0AA0
; DATE  : 23-Jan-2015
;======================================================
;
#Profibus_DP
;
;----General parameters----------------------------------------------

GSD_Revision         = 5
Vendor_Name          = "Siemens"
Model_Name           = "EM DP01 PROFIBUS-DP"
Revision             = "V01.00.00"
Ident_Number         = 0x81C7
Protocol_Ident       = 0
Station_Type         = 0
FMS_supp             = 0
Hardware_Release     = "1"
Software_Release     = "V01.00.00"
;
9.6_supp             = 1
19.2_supp            = 1
45.45_supp           = 1
93.75_supp           = 1
187.5_supp           = 1
500_supp             = 1
1.5M_supp            = 1
3M_supp              = 1
6M_supp              = 1
12M_supp             = 1
;
MaxTsdr_9.6          = 40
MaxTsdr_19.2         = 40
MaxTsdr_45.45        = 40
MaxTsdr_93.75        = 40
MaxTsdr_187.5        = 40
MaxTsdr_500          = 40
MaxTsdr_1.5M         = 40
MaxTsdr_3M           = 50
MaxTsdr_6M           = 100
MaxTsdr_12M          = 200
;
Redundancy           = 0
Repeater_Ctrl_Sig    = 2
24V_Pins             = 2
Implementation_Type  = "DPC31"
Bitmap_Device        = "EM_DP01N"

;----Slave-Specification---------------------------------------------

OrderNumber          = "6ES7 288-7DP01-0AA0"
Periphery            = "SIMATIC S7"
Info_Text            = "PROFIBUS module for SMART CPU family."
Slave_Family         = 10@TdF@SIMATIC

Freeze_Mode_supp     = 1
Sync_Mode_supp       = 1
Set_Slave_Add_Supp   = 0
Auto_Baud_supp       = 1
Min_Slave_Intervall  = 1
Fail_Safe            = 0
;
Modular_Station      = 1
Max_Module           = 2
Modul_Offset         = 0
;
Max_Input_Len        = 244
Max_Output_Len       = 244
Max_Data_Len         = 488
Max_Diag_Data_Len    = 6

;----DPV1 support----------------------------------------------------

DPV1_Slave              = 1
C1_Read_Write_supp      = 1
C2_Read_Write_supp      = 1
C1_Max_Data_Len         = 240
C2_Max_Data_Len         = 240
C1_Response_Timeout     = 100
C2_Response_Timeout     = 100
C1_Read_Write_required  = 0
C2_Read_Write_required  = 0
C2_Max_Count_Channels   = 6
Max_Initiate_PDU_Length = 64

Ident_Maintenance_supp  = 1

DPV1_Data_Types         = 0
WD_Base_1ms_supp        = 0
Check_Cfg_Mode          = 0
Publisher_supp          = 0

;----UserPrmData-Definition------------------------------------------

ExtUserPrmData = 1 "I/O Offset in the V-memory"
Unsigned16 0 0-20479
EndExtUserPrmData

;----UserPrmData: Length and Preset----------------------------------

Max_User_Prm_Data_Len=5
Ext_User_Prm_Data_Const(0)=0x80,0x00,0x00,0x00,0x00
Ext_User_Prm_Data_Ref(3)=1

;----Module Definition List------------------------------------------

Module = "  4 Bytes In/Out"     0xF1
20
EndModule

Module = "  8 Bytes In/Out"     0xF3
21
EndModule

Module = " 16 Bytes In/Out"     0xF7
22
EndModule

Module = " 32 Bytes In/Out"     0xFF
23
EndModule

Module = " 64 Bytes In/Out"     0xC0,0xDF,0xDF
24
EndModule

Module = "122 Bytes In/Out"     0xC0,0xFC,0xFC
25
EndModule

Module = "128 Bytes In/Out"     0xC0,0xFF,0xFF
26
EndModule

Категория: SIEMENS | Просмотров: 5 | Добавил: gt7600 | Рейтинг: 5.0/1