INVTV2DP_05_09_2022.zip - INVTV2DP_05_09_2022.gsd
IPE300.rar - GD270 / GD350 / GD880 / IPE300 INVTV2DP.gsd Date : 2015-08-07 INVT-6SE70"
GD800_Pro.rar - INVTV2DP.gsd Date : 2013-06-16 "INVT-6SE70"
GD600.rar - 600DP100.gsd
;============================================================
; Profibus Device Database of INVT.
; Description : INVT Profibus DP slave
; Language : English
; Date : 2015-08-07
; Author : mango @ INVT
;============================================================
#Profibus_DP
GSD_Revision = 4
; Device identification
Vendor_Name = "INVT ELECTRIC CO., LTD"
Model_Name = "INVT-6SE70"
Revision = "Version 2.0"
Ident_Number = 0x0D55
Protocol_Ident = 0 ; DP protocol
Station_Type = 0 ; Slave device
FMS_supp = 0 ; FMS not supported
Hardware_Release = "Version 2.0"
Software_Release = "Version 2.0" ;MCU CPU M4
; Supported baudrates
9.6_supp = 1
19.2_supp = 1
45.45_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
; Maximum responder time for supported baudrates
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_45.45 = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
; Supported hardware features
Redundancy = 0 ; not supported
Repeater_Ctrl_Sig = 0 ; TTL
24V_Pins = 0 ; not connected
Implementation_Type = "VPC3"
; Supported DP features
Freeze_Mode_supp = 1 ; supported
Sync_Mode_supp = 1 ; supported
Auto_Baud_supp = 1 ; supported
Set_Slave_Add_supp = 0 ; not supported
; Maximum polling frequency
Min_Slave_Intervall = 6 ; 100 us
; Maximum supported sizes
Modular_Station = 1 ; modular
Max_Module = 1
Max_Input_Len = 32
Max_Output_Len = 32
Max_Data_Len = 64
Modul_Offset = 1
Fail_Safe = 0 ; Slave does not accept data frames with zero data length in state CLEAR.
Slave_Family = 0@INVT
Max_Diag_Data_Len = 6
; Definition of modules
Module = "PKW module " 0xF3
30
EndModule
Module = "PPO 1: 4 PKW , 2 PZD " 0xF3, 0xF1
31
EndModule
Module = "PPO 2: 4 PKW , 6 PZD " 0xF3, 0xF5
32
EndModule
Module = "PPO 3: 0 PKW , 2 PZD " 0x00, 0xF1
33
EndModule
Module = "PPO 4: 0 PKW , 6 PZD " 0x00, 0xF5
34
EndModule
Module = "PPO 5: 4 PKW , 10 PZD " 0xF3, 0xF9
35
EndModule
Module = "IN/OUT: 32 Byte (16 word)" 0xFF
36
EndModule
;==================================================================================== |