; GSD File    : TS8000 Profibus Option Card

; Part Number : 8000/PB/00
;
; SSD Drives
; 9225 Forsyth Park Drive
; Charlotte NC 28273
; United States of America
;            
; Version:  V1.1
;======================================================
#Profibus_DP

;General parameters
GSD_Revision    = 2
Vendor_Name     = "SSD Drives"
Model_Name      = "TS8000 Profibus Option Card"
OrderNumber     = "8000PB00"
Revision        = "V1.1"
Ident_Number    = 0x09EA
Protocol_Ident  = 0
Station_Type    = 0
FMS_supp        = 0
Hardware_Release= "Rev. A"
Software_Release= "1.0"
9.6_supp        = 1
19.2_supp       = 1
45.45_supp      = 1
93.75_supp      = 1
187.5_supp      = 1
500_supp        = 1
1.5M_supp       = 1
3M_supp         = 1
6M_supp         = 1
12M_supp        = 1
MaxTsdr_9.6     = 60
MaxTsdr_19.2    = 60
MaxTsdr_45.45   = 250
MaxTsdr_93.75   = 60
MaxTsdr_187.5   = 60
MaxTsdr_500     = 100
MaxTsdr_1.5M    = 150
MaxTsdr_3M      = 250
MaxTsdr_6M      = 450
MaxTsdr_12M     = 800
Redundancy      = 0
Repeater_Ctrl_Sig    = 1
24V_Pins             = 0
Implementation_Type  = "VPC3"
Bitmap_Device        = "TS09EAN"
Bitmap_Diag          = "TS09EAD"
Bitmap_SF            = "TS09EAS"

; Slave-Specification:
Freeze_Mode_supp     = 0
Sync_Mode_supp       = 0
Set_Slave_Add_Supp   = 0
Auto_Baud_supp       = 1
Min_Slave_Intervall  = 1
Fail_Safe            = 0
Max_Diag_Data_Len    = 6
Modul_Offset         = 0
Slave_Family         = 6
Modular_Station      = 1
Max_Module           = 1
Max_Input_len        = 128
Max_Output_len       = 128
Max_Data_len         = 256

; UserPrmData: Length and Preset:
User_Prm_Data_Len    = 05
User_Prm_Data        = 0x00, 0x00, 0x00, 0x00, 0x01

; Module Definition List
Module               = "64 Words Out, 64 Words In" 0xC0, 0x7F, 0x7F
EndModule

Module               = "8 Words Out, 8 Words In" 0xC0, 0xC7, 0xC7
EndModule

Module               = "5 Words Out, 5 Words In" 0xC0, 0xC4, 0xC4
EndModule

Module               = "9 Bytes Out, 9 Bytes In" 0xC0, 0x88, 0x88
EndModule

Module               = "1 Word Out, 1 Word In" 0xF0
EndModule