PAUT1110.zip
;===============================================================================
; Process Automation Profibus GSD file for the Model 166 Profibus PA Interface
;
; Model: Model 166 Profibus PA Interface
; Description: Model 166 Profibus PA slave
; Language: English
; Author: Process Automation (Pty) Ltd.
; WWW: www.process-auto.com
;
; Revisions:
; Rev 00 - Initial version. ict
; Rev 01 - Revised - 21 January 2019. ict
;===============================================================================
;===============================================================================
;
; Process Automation Profibus GSD file for the Model 166 Profibus PA Interface
;
; Model: Model 166 Profibus PA Interface
; Description: Model 166 Profibus PA slave
; Language: English
; Author: Process Automation (Pty) Ltd.
; WWW: www.process-auto.com
;
; Revisions:
; Rev 00 - Initial version. ict
; Rev 01 - Revised - 21 January 2019. ict
;
;===============================================================================
#Profibus_DP
GSD_Revision = 5
Vendor_Name = "Process Automation (Pty) Ltd."
Model_Name = "Model 166 Profibus PA Interface"
Revision = "1.0"
Ident_Number = 0x1110
Protocol_Ident = 0 ; DP protocol
Station_Type = 0 ; Slave device
FMS_supp = 0 ; FMS not supported
Hardware_Release = "0.00"
Software_Release = "0.00"
Bitmap_Device = "-"
31.25_supp = 1
45.45_supp = 1
93.75_supp = 1
MaxTsdr_31.25 = 100
MaxTsdr_45.45 = 250
MaxTsdr_93.75 = 1000
Redundancy = 0 ; N/A
Repeater_Ctrl_Sig = 0 ; N/A
24V_Pins = 0 ; N/A
Implementation_Type = "DPC31"
Freeze_Mode_supp = 0 ; Not supported
Sync_Mode_supp = 0 ; Not supported
Set_Slave_Add_supp = 0 ; Not supported
Min_Slave_Intervall = 250
Modular_Station = 1
Max_Module = 15
Max_Input_Len = 75 ; maximum Input Length
Max_Output_Len = 0 ; maximum Output Length
Max_Data_Len = 75 ; maximum In-Output Length
Slave_Family = 12
Max_Diag_Data_Len = 14
Max_User_Prm_Data_Len = 3
Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00
;----------- Description of extended DP features: ---------------------
;
DPV1_Slave = 1
Ident_Maintenance_supp = 0 ; Not supported
C2_Read_Write_supp = 0 ; Not supported
;C2_Max_Data_Len = 128
;C2_Read_Write_required = 1
;C2_Max_Count_Channels = 1
;Max_Initiate_PDU_Length = 52
;C2_Response_Timeout = 4000
DPV1_Data_Types = 1
C1_Read_Write_supp = 0 ; Not supported
;C1_Max_Data_Len = 68
;C1_Response_Timeout = 100 ;1 sec
;--- Description of physical interface for async. and sync. transmission: ---
Physical_Interface = 0 ; RS-485 Standard Copper
Transmission_Delay_45.45 = 0
Reaction_Delay_45.45 = 0
Transmission_Delay_93.75 = 0
Reaction_Delay_93.75 = 0
End_Physical_Interface
;
Physical_Interface = 1 ; IEC61158-2
Transmission_Delay_31.25 = 0
Reaction_Delay_31.25 = 0
End_Physical_Interface
;----------- Description of device related diagnosis: ---------------------
;
Unit_Diag_Bit(16) = "Error appears"
Unit_Diag_Bit(17) = "Error disappears"
Unit_Diag_Bit(24) = "Hardware failure electronics"
Unit_Diag_Bit(25) = "Hardware failure mechanics"
Unit_Diag_Bit(26) = "Motor temperature too high"
Unit_Diag_Bit(27) = "Electronic temperature too high"
Unit_Diag_Bit(28) = "Memory error"
Unit_Diag_Bit(29) = "Measurement failure"
Unit_Diag_Bit(30) = "Device not initialized"
Unit_Diag_Bit(31) = "Device initialization failed"
Unit_Diag_Bit(32) = "Zero point error"
Unit_Diag_Bit(33) = "Power supply failed"
Unit_Diag_Bit(34) = "Configuration invalid"
Unit_Diag_Bit(35) = "Restart"
Unit_Diag_Bit(36) = "Coldstart"
Unit_Diag_Bit(37) = "Maintenance required"
Unit_Diag_Bit(38) = "Characteristics invalid"
Unit_Diag_Bit(39) = "Ident_Number violation"
Unit_Diag_Bit(55) = "Extension Available"
;-------------------------------------------------------------------------
;Empty module
Module = "Empty Module" 0x00
1
EndModule
;
;Modules for Analog Input
Module = "Analog Input (AI)" 0x94
2
EndModule
;
;-------------------------------------------------------------------------
;-------------------------------------------------------------------------
;------------------------------------------------------------------------- |