PLC, HMI, SCADA, INVERTERS, GSD PROFIBUS,
GSDML PROFINET, EDS CanOpen, INDUSTRIAL AUTOMATION

SIMATIC_DSAFETY_V5_4_SP5_Upd2.exe

This option package contains two products:

  • S7 Distributed Safety Programming V 5.4 + SP5
  • S7 F-Configuration Pack V5.5 SP13

Software requirements

STEP 7 V5.5 SP1 or higher

The following operating systems are supported:

  • Windows Server 2008 R2 StdE SP1 64-bit (full installation)
  • Windows Server 2012 R2 StdE 64-bit (full installation)
  • Windows Server 2016 64-bit Standard (full installation)
  • Windows 7 SP1 64-bit (Ultimate, Professional or Enterprise)
  • Windows 10 Pro Version 1607 64-bit (OS Build 14393)
  • Windows 10 Enterprise Version 1607 64-bit (OS Build 14393)
  • Windows 10 Enterprise 2015 LTSB 64-bit (OS Build 10240)
  • Windows 10 IoT Enterprise 2015 LTSB 64-bit (OS Build 10240) (for IPC/PG)
Категория: SIEMENS | Просмотров: 121 | Добавил: gt7600 | Дата: 13.09.2026 | Комментарии (0)

Entry type: Download Entry ID: 109750220, Entry date: 09/06/2017
Download of firmware 1.3.8 for CM 1243-5 PROFIBUS
Примечание

Для обновления микропрограммного обеспечения (прошивки) доступны два файла.

Используйте файл `6GK7 243-5DX30-0XE0 V01.03.08.upd`, если модуль CM 1243-5 установлен рядом с ЦПУ S7-1200, имеющим версию прошивки V3 или более раннюю.
Используйте файл `6GK7 243-5DX30-0XE0 V01.03.08_V4CPU.upd`, если модуль CM 1243-5 установлен рядом с ЦПУ S7-1200, имеющим версию прошивки V4.
Необходимые действия пользователя:

Обновление прошивки можно выполнить через веб-сервер или с помощью функций онлайн-диагностики STEP 7, либо путем подготовки карты памяти SIMATIC (файл обновления скачивается с сайта службы поддержки клиентов Siemens). Эта процедура описана в руководстве по системе S7-1200.

При использовании карты памяти SIMATIC для обновления прошивки данные в энергонезависимой памяти (retentive memory) сохраняются. Однако при обновлении через веб-сервер или функции онлайн-диагностики STEP 7 данные в энергонезависимой памяти теряются.

Если закрыть веб-сервер во время выполнения обновления прошивки, перевести ЦПУ в режим RUN будет невозможно. В этом случае для перевода ЦПУ в режим RUN необходимо выключить и снова включить питание контроллера.

Обновление прошивки модулей CM 1243-5 с версией ниже 1.3.3 необходимо выполнять с использованием карты памяти.

6GK7_243-5DX30-0XE0_V01.03.08_V4CPU.zip (4.5 MB)
6GK7_243-5DX30-0XE0_V01.03.08.zip (4.7 MB)

Категория: SIEMENS | Просмотров: 75 | Добавил: gt7600 | Дата: 12.09.2026 | Комментарии (0)

SIEMENS Sinamics G120 GSDML PROFINET GSDML-V2.25-Siemens-Sinamics_G120

GSDML-V2.25-Siemens-Sinamics_G120-20170904.xml

GSDML-V2.31-Siemens-Sinamics_G120-20170904.xml

для 6SL3 244-0BB12-1FA0 Firmware Version: V04.71.52.21 SINAMICS-G120-CU240E-2PN

PNGSD_Sinamics_G120-20170904.zip

Категория: SIEMENS | Просмотров: 94 | Добавил: gt7600 | Дата: 10.09.2026 | Комментарии (0)

Firmware V3.2.x

g120_cu240spn-f_v3_2_1.zip (7,0 KB) - GSDML-V2.0-siemens-sinamicsg120prof-20090122.xml

Firmware V3.2

g120_cu240spn-f_v3_2.zip (7,2 KB) - gsdml-v2.0-siemens-sinamicsg120prof-20080514.xml

Firmware V3.1

g120_cu240spn-f_v3_1.zip (7,1 KB) - gsdml-v2.0-siemens-sinamicsg120prof-20070803.xml

Категория: SIEMENS | Просмотров: 104 | Добавил: gt7600 | Дата: 06.09.2026 | Комментарии (0)

Firmware V3.2.x

 g120_cu240spn_v3_2_1.zip (5,1 KB) - GSDML-V2.0-siemens-sinamicsg120-20090122.xml 

Firmware V3.2

g120_cu240spn_v3_2.zip (5,2 KB) - gsdml-v2.0-siemens-sinamicsg120-20080514.xml

Firmware V3.1

g120_cu240spn_v3_1.zip (5,1 KB) - gsdml-v2.0-siemens-sinamicsg120-20070803.xml

Категория: SIEMENS | Просмотров: 90 | Добавил: gt7600 | Дата: 06.09.2026 | Комментарии (0)

GSDML-V2.25-Siemens-Sinamics_G120S_Vector-20200511.xml

GSDML-V2.31-Siemens-Sinamics_G120S_Vector-20200511.xml

G120_GSDML_CU250S_PN_V4.7_SP13.zip

Категория: SIEMENS | Просмотров: 115 | Добавил: gt7600 | Дата: 06.09.2026 | Комментарии (0)

Инструкция по обновлению ПО RUGGEDCOM RS900

План действий и необходимые компоненты:

Программы:

  • PuTTY (или аналогичный эмулятор терминала) для доступа к интерфейсу командной строки (CLI) через консольный порт;
  • Tftpd64 (или другой TFTP-сервер) для передачи файлов прошивки на коммутатор по сети.

Файлы прошивки: Полученные от представителя Siemens файлы для вашей модели. Обычно это ROS-CF52_Boot_v4.3.0.zb (загрузчик) и ROS-CF52_Main_v5.10.0.zb (основная прошивка)  ... Читать дальше »

Категория: SIEMENS | Просмотров: 211 | Добавил: gt7600 | Дата: 03.08.2026 | Комментарии (0)

SIEMENS 46817803 Sending Emails to SMTP Servers with an S7 CPU S7-1500

46817803_Archiv_en.zip - In the archive, you will find the documentation and sample projects for sending unsecure emails with the FB "PN_Mail".

46817803_Email_with_SimaticS7.zip - Sample project for TIA Portal V17 (835,8 KB)

46817803_EMail_with_SimaticS7_V3_2_en.pdf - APPLICATION EXAMPLE Sending of emails over secure connections with S7-1500 and S7-1200 PLCs / Entry-ID: 46817803 V3.2 04/2026   ... Читать дальше »

Категория: SIEMENS | Просмотров: 423 | Добавил: gt7600 | Дата: 24.07.2026 | Комментарии (0)