Systeme LAUER GmbH & CoKG LAUSPC3X.GSD LAUSPC3X.200 PCS 807-Modul SPC3

Systeme LAUER GmbH & CoKG LAUSPC3X.GSD LAUSPC3X.200 PCS 807-Modul SPC3

Lauer Operator Panels PCS 807-Modul SPC3
the legacy LAUSPC3X.200 descriptor, and modern *.GSD files such as LCAPCS31.GSD used for the PCS807 series

LCAPCS31_GSD.zip - LAUSPC3X.GSD LAUSPC3X.200 

;*************************************************************************
;***                                                                   ***
;***      Systeme LAUER GmbH & CoKG                                           ***
;***      D-72669 Unterensingen                                        ***
;***      KelterstraЯe 59                                              ***
;***         Tel.: 07022/9660-0                                        ***
;***          Fax: 07022/9660-103                                      ***
;***      Hotline: 07022/9660-220 - 223/226                            ***
;***          Fax: 07022/9669-224                                      ***
;***                                                                   ***
;*************************************************************************
;***                                                                   ***
;***      Filename: LAUSPC3X.GSD                  (c) 1998             ***
;***      Version 1.1      from  24.09.1998                            ***
;***                                                                   ***
;*************************************************************************
;
;      ATTENTION:
;      ==========
;      Changes in this file can cause configuration or communicationproblems.
;      
;      WICHTIGER HINWEIS
;      =================
;      Eine unsachgemдЯe Verдnderung der Parameter kann zu undefiniertem
;      Systemverhalten des DP-Busses fьhren und geschieht in eigener
;      Verantwortung !
;
;
;
#Profibus_DP
Vendor_Name         = "Systeme Lauer GmbH"
Model_Name          = "PCS 807-Modul SPC3"
Revision            = "Version 1.100"
Ident_Number        = 0x0008
Protocol_Ident      = 0
Station_Type        = 0
Hardware_Release    = "Version -.---"
Software_Release    = "Version -.---"
9.6_supp            = 1
19.2_supp           = 1
93.75_supp          = 1
187.5_supp          = 1
500_supp            = 1
1.5M_supp           = 1
3M_supp             = 1
6M_supp             = 1
12M_supp            = 1
;
MaxTsdr_9.6         = 60
MaxTsdr_19.2        = 60
MaxTsdr_93.75       = 60
MaxTsdr_187.5       = 60
MaxTsdr_500         = 100
MaxTsdr_1.5M        = 150
MaxTsdr_3M          = 250
MaxTsdr_6M          = 450
MaxTsdr_12M        = 800
;
Redundancy          = 0
Repeater_Ctrl_Sig   = 0
24V_Pins            = 0
Freeze_Mode_supp    = 1
Sync_Mode_supp      = 1
Auto_Baud_supp      = 1
Set_Slave_Add_supp  = 0
User_Prm_Data_Len   = 0
;User_Prm_Data       =
Min_Slave_Intervall = 5
Modular_Station     = 1
Max_Module          = 2
Max_Input_Len       = 0x20
Max_Output_Len      = 0x20
Max_Data_Len        = 0x40
;
Max_Diag_Data_Len=32
;
Module = "blank space (0x00)" 0x00
EndModule
;
;*************************************************************************
;***                input byte with consistence                        ***
;*************************************************************************
;
Module = "8  byte input con  (0x97)" 0x97
EndModule
Module = "16 byte input con  (0x9F)" 0x9F
EndModule
Module = "24 byte input con  (0x9F,0x97)" 0x9F,0x97
EndModule
Module = "32 byte input con  (0x9F,0x9F)" 0x9F,0x9F
EndModule
;
;*************************************************************************
;***                output byte with consistence                       ***
;*************************************************************************
;
Module = "8  byte output con (0xA7)" 0xA7
EndModule
Module = "16 byte output con (0xAF)" 0xAF
EndModule
Module = "24 byte output con (0xAF,0xA7)" 0xAF,0xA7
EndModule
Module = "32 byte output con (0xAF,0xAF)" 0xAF,0xAF
EndModule
;
;*************************************************************************
;***                input byte without consistence                     ***
;*************************************************************************
;
Module = "8  byte input   (0x17)" 0x17
EndModule
Module = "16 byte input   (0x1F)" 0x1F
EndModule
Module = "24 byte input   (0x1F,0x17)" 0x1F,0x17
EndModule
Module = "32 byte input   (0x1F,0x1F)" 0x1F,0x1F
EndModule
;
;*************************************************************************
;***                output byte without consistence                    ***
;*************************************************************************
;
Module = "8  byte output  (0x27)" 0x27
EndModule
Module = "16 byte output  (0x2F)" 0x2F
EndModule
Module = "24 byte output  (0x2F,0x27)" 0x2F,0x27
EndModule
Module = "32 byte output  (0x2F,0x2F)" 0x2F,0x2F
EndModule