PLC, HMI, SCADA, INVERTERS, TUTORIALS, INDUSTRIAL AUTOMATION

22:57
Bosch Rexroth RX010161.gsd GSD for CML40 PROFIBUS DP slave

GSD_L40_RX010161_200512.zip - RX010161.gsd GSD for CML40 PROFIBUS DP slave 

;******************************************************************************
;      Bosch Rexroth AG
;      The Drives & Control Company
;      Electric Drives and Controls
;      
;      Berliner Str. 25
;      D-64711 Erbach
;******************************************************************************
; GSD-File for: IndraControl DP-Slave
; Device      : CML40
; Material-No.: 1070.170.261
;******************************************************************************
; File Name   : RX010161.GSD
; File Version: 1.05
; File Date   : 13.12.2005
;******************************************************************************
;************** File History **************************************************
; Date          File Version
; 26.01.2005                 First Release
; 10.02.2005                 User_Prm_Data_Len = 3    
; 09.08.2005    1.01         Fail_Safe = 0   
; 22.09.2005    1.02         Max_Diag_Data_Len = 20; discard some comments 
; 26.09.2005    1.02         Header comments
; 12.10.2005    1.03         Sync_Mode_supp = 0  (before: 1)
; 14.10.2005    1.04         Slave_Family=10@Rexroth (now 10-SPS before: 3-IO)
; 13.12.2005    1.05         GSD_Revision = 3 and new entries
;******************************************************************************
;******************************************************************************
;
;      DISCLAIMER:
;      ===========
;
;      DO NOT MODIFY THIS FILE!
;      CHANGING PROFIBUS PARAMETERS CAN LEAD TO UNDEFINED SYSTEM BEHAVIOUR
;
;******************************************************************************

#Profibus_DP

;*************************************************************************
; General Data
;*************************************************************************
GSD_Revision = 3
Vendor_Name = "Rexroth"
Model_Name = "L40 DPV1 Slave"
Revision = "1.0"
Revision_Number = 0x01
Ident_Number = 0x0161
Protocol_Ident = 0  ; PROFIBUS DP
Station_Type = 0    ; DP Slave
Hardware_Release = "V 1.0"
Software_Release = "V 1.0"

; Supported Data Rates
9.6_supp   = 1
19.2_supp  = 1
31.25_supp = 0
45.45_supp = 0
93.75_supp = 1
187.5_supp = 1
500_supp   = 1
1.5M_supp  = 1
3M_supp    = 1
6M_supp    = 1
12M_supp   = 1

; Maximum Response Time
MaxTsdr_9.6   = 60
MaxTsdr_19.2  = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500   = 100
MaxTsdr_1.5M  = 150
MaxTsdr_3M    = 250
MaxTsdr_6M    = 450
MaxTsdr_12M   = 800

Repeater_Ctrl_Sig = 2 ; TTL
Implementation_Type = "ASPC2"

; Bitmap file for standard representation
Bitmap_Device = "RX_R0161"
; Bitmap file for diagnostic cases
Bitmap_Diag = "RX_D0161"
; Bitmap file for special operating modes
Bitmap_SF = "RX_S0161"

;*************************************************************************
; Specific Data of Slave
;*************************************************************************
Freeze_Mode_supp=0
Sync_Mode_supp = 0
Auto_Baud_supp = 1
Set_Slave_Add_supp = 0
Min_Slave_Intervall = 6
Modular_Station = 1
Max_Module = 2
Max_Input_Len = 128
Max_Output_Len = 128
Max_Data_Len = 256
Fail_Safe = 0
Max_Diag_Data_Len = 20
Slave_Family=10@Rexroth

;*************************************************************************
; Slave specific Diagnostics
;*************************************************************************
Unit_Diag_Bit(0) = "Remote PLC in STOP State"
Unit_Diag_Bit(1) = "Remote PLC in CLAB"

; begin new 13.12.2005
; DPV1
DPV1_Slave=1
DPV1_Data_Types=0
C1_Read_Write_supp=1
C1_Max_Data_Len=240
C1_Response_Timeout=500
Max_Initiate_PDU_Length=0
; end new 13.12.2005

;*************************************************************************
; Parameter Data of DP Slave
;*************************************************************************

; Angaben fuer GSD-Dateien kleiner Revision 1
; -------------------------------------------
;User_Prm_Data_Len = 0           ; Laenge herstellerspezifisches Feld
User_Prm_Data_Len = 3            ; Laenge herstellerspezifisches Feld
User_Prm_Data = 0x80,0x00,0x00   ; Grundeinstellungen

;*************************************************************************
; Configurable Modules of Slave
;*************************************************************************
; Input Modules
Module = "8 Byte Input" 0x40,0x87        ;bit7 Konsistenz(1) bit6 Byte(0)/Wort(1) bit5..0 (1..64)
1
EndModule
Module = "16 Byte Input" 0x40,0x8F
2
EndModule
Module = "24 Byte Input" 0x40,0x97
3
EndModule
Module = "32 Byte Input" 0x40,0x9F
4
EndModule
Module = "40 Byte Input" 0x40,0xA7
5
EndModule
Module = "48 Byte Input" 0x40,0xAF
6
EndModule
Module = "56 Byte Input" 0x40,0xB7
7
EndModule
Module = "64 Byte Input" 0x40,0xBF
8
EndModule
; Output Modules
Module = "8 Byte Output" 0x80,0x87
9
EndModule
Module = "16 Byte Output" 0x80,0x8F
10
EndModule
Module = "24 Byte Output" 0x80,0x97
11
EndModule
Module = "32 Byte Output" 0x80,0x9F
12
EndModule
Module = "40 Byte Output" 0x80,0xA7
13
EndModule
Module = "48 Byte Output" 0x80,0xAF
14
EndModule
Module = "56 Byte Output" 0x80,0xB7
15
EndModule
Module = "64 Byte Output" 0x80,0xBF
16
EndModule

;********************* End of GSD File *******************